{"product_id":"replacement-user-interface-control-panel-for-hp41-hp42-and-hp75c-pellet-stoves","title":"Replacement User Interface Control Panel for HP41, HP42, and HP75C Pellet Stoves","description":"\u003cp data-start=\"333\" data-end=\"632\"\u003eThis \u003cstrong data-start=\"338\" data-end=\"382\"\u003eReplacement User Interface Control Panel\u003c\/strong\u003e is engineered specifically for \u003cstrong data-start=\"414\" data-end=\"460\"\u003eAlpine HP41, HP42, and HP75c pellet stoves\u003c\/strong\u003e. These models use a \u003cstrong data-start=\"481\" data-end=\"524\"\u003ethermocouple-based Proof of Fire system\u003c\/strong\u003e, which is fundamentally different from standard ComfortBilt panels that rely on a heat-activated snap disc.\u003c\/p\u003e\n\u003cp data-start=\"634\" data-end=\"785\"\u003e⚠️ \u003cstrong data-start=\"637\" data-end=\"728\"\u003eThis control panel is NOT interchangeable with standard ComfortBilt replacement panels.\u003c\/strong\u003e Programming differences make correct selection critical.\u003c\/p\u003e\n\u003chr data-start=\"787\" data-end=\"790\"\u003e\n\u003ch3 data-start=\"792\" data-end=\"835\"\u003e🔥 Proof of Fire Programming Difference\u003c\/h3\u003e\n\u003cp data-start=\"836\" data-end=\"960\"\u003eThis control panel is \u003cstrong data-start=\"858\" data-end=\"932\"\u003eprogrammed to interpret a temperature range from a thermocouple sensor\u003c\/strong\u003e to establish Proof of Fire.\u003c\/p\u003e\n\u003cul data-start=\"962\" data-end=\"1053\"\u003e\n\u003cli data-start=\"962\" data-end=\"1017\"\u003e\n\u003cp data-start=\"964\" data-end=\"1017\"\u003eThermocouple-based \u003cstrong data-start=\"983\" data-end=\"1017\"\u003etemperature range verification\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1018\" data-end=\"1053\"\u003e\n\u003cp data-start=\"1020\" data-end=\"1053\"\u003eContinuous temperature monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1055\" data-end=\"1102\"\u003eStandard ComfortBilt panels are programmed for:\u003c\/p\u003e\n\u003cul data-start=\"1103\" data-end=\"1174\"\u003e\n\u003cli data-start=\"1103\" data-end=\"1133\"\u003e\n\u003cp data-start=\"1105\" data-end=\"1133\"\u003eHeat-activated \u003cstrong data-start=\"1120\" data-end=\"1133\"\u003esnap disc\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1134\" data-end=\"1174\"\u003e\n\u003cp data-start=\"1136\" data-end=\"1174\"\u003eSimple \u003cstrong data-start=\"1143\" data-end=\"1167\"\u003eyes\/no (open\/closed)\u003c\/strong\u003e signal\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1176\" data-end=\"1265\"\u003eUsing the incorrect panel type will result in \u003cstrong data-start=\"1222\" data-end=\"1264\"\u003eimproper startup or failure to operate\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr data-start=\"1267\" data-end=\"1270\"\u003e\n\u003ch3 data-start=\"1272\" data-end=\"1322\"\u003e⚠️ Compatibility Notice — READ BEFORE ORDERING\u003c\/h3\u003e\n\u003ch4 data-start=\"1324\" data-end=\"1347\"\u003eHP41 \u0026amp; HP42 Models\u003c\/h4\u003e\n\u003cp data-start=\"1348\" data-end=\"1507\"\u003eThere are \u003cstrong data-start=\"1358\" data-end=\"1374\"\u003etwo versions\u003c\/strong\u003e of this control panel for HP41 and HP42 stoves. Compatibility is determined by the \u003cstrong data-start=\"1458\" data-end=\"1506\"\u003ePCM (Power Control Module) transformer color\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cul data-start=\"1509\" data-end=\"1688\"\u003e\n\u003cli data-start=\"1509\" data-end=\"1593\"\u003e\n\u003cp data-start=\"1511\" data-end=\"1593\"\u003e\u003cstrong data-start=\"1511\" data-end=\"1525\"\u003eVersion A:\u003c\/strong\u003e Compatible with PCM boards that have a \u003cstrong data-start=\"1565\" data-end=\"1593\"\u003efully yellow transformer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1594\" data-end=\"1688\"\u003e\n\u003cp data-start=\"1596\" data-end=\"1688\"\u003e\u003cstrong data-start=\"1596\" data-end=\"1610\"\u003eVersion B:\u003c\/strong\u003e Compatible with PCM boards that have a \u003cstrong data-start=\"1650\" data-end=\"1688\"\u003ehalf-yellow \/ half-red transformer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1690\" data-end=\"1818\"\u003eThe transformer color is \u003cstrong data-start=\"1715\" data-end=\"1759\"\u003evisible through the square cutout window\u003c\/strong\u003e on the PCM board lid and must be verified before ordering.\u003c\/p\u003e\n\u003ch4 data-start=\"1820\" data-end=\"1836\"\u003eHP75c Model\u003c\/h4\u003e\n\u003cul data-start=\"1837\" data-end=\"1979\"\u003e\n\u003cli data-start=\"1837\" data-end=\"1874\"\u003e\n\u003cp data-start=\"1839\" data-end=\"1874\"\u003eUses \u003cstrong data-start=\"1844\" data-end=\"1874\"\u003eone PCM board version only\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1875\" data-end=\"1935\"\u003e\n\u003cp data-start=\"1877\" data-end=\"1935\"\u003e\u003cstrong data-start=\"1877\" data-end=\"1935\"\u003eNo transformer-based compatibility issues at this time\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1936\" data-end=\"1979\"\u003e\n\u003cp data-start=\"1938\" data-end=\"1979\"\u003eOnly one control panel option is required\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1981\" data-end=\"1984\"\u003e\n\u003ch3 data-start=\"1986\" data-end=\"2043\"\u003eCompatible PCM \/ Motherboard Versions (For Reference)\u003c\/h3\u003e\n\u003cp data-start=\"2044\" data-end=\"2107\"\u003eUse the links below to visually confirm your PCM board version:\u003c\/p\u003e\n\u003cul data-start=\"2109\" data-end=\"2225\"\u003e\n\u003cli data-start=\"2109\" data-end=\"2161\"\u003e\n\u003cp data-start=\"2111\" data-end=\"2161\"\u003e\u003cstrong data-start=\"2111\" data-end=\"2150\"\u003ePCM Board:\u003c\/strong\u003e\u003cbr data-start=\"2150\" data-end=\"2153\"\u003e\u003ca href=\"https:\/\/www.comfortbilt.net\/products\/comfortbilt-pellet-stove-replacement-user-interface-control-panel-copy?_pos=1\u0026amp;_psq=motherboard\u0026amp;_ss=e\u0026amp;_v=1.0\"\u003ehttps:\/\/www.comfortbilt.net\/products\/comfortbilt-pellet-stove-replacement-user-interface-control-panel-copy?_pos=1\u0026amp;_psq=motherboard\u0026amp;_ss=e\u0026amp;_v=1.0\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong data-start=\"2111\" data-end=\"2150\"\u003e4 Wire Data Cable:\u003c\/strong\u003e\u003cbr data-start=\"2150\" data-end=\"2153\"\u003e\u003ca href=\"https:\/\/www.comfortbilt.net\/products\/comfortbilt-pellet-stove-4-pin-data-cable\"\u003ehttps:\/\/www.comfortbilt.net\/products\/comfortbilt-pellet-stove-4-pin-data-cable\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2227\" data-end=\"2342\"\u003e👉 HP41 and HP42 models \u003cstrong data-start=\"2251\" data-end=\"2314\"\u003emust match both the stove model and PCM transformer version\u003c\/strong\u003e selected from the dropdown.\u003c\/p\u003e\n\u003chr data-start=\"2344\" data-end=\"2347\"\u003e\n\u003ch3 data-start=\"2349\" data-end=\"2374\"\u003e❌ Not Compatible With\u003c\/h3\u003e\n\u003cul data-start=\"2375\" data-end=\"2517\"\u003e\n\u003cli data-start=\"2375\" data-end=\"2414\"\u003e\n\u003cp data-start=\"2377\" data-end=\"2414\"\u003eStandard ComfortBilt control panels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2415\" data-end=\"2450\"\u003e\n\u003cp data-start=\"2417\" data-end=\"2450\"\u003eSnap-disc Proof of Fire systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2451\" data-end=\"2517\"\u003e\n\u003cp data-start=\"2453\" data-end=\"2517\"\u003ePCM boards or wiring configurations outside those listed above\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2519\" data-end=\"2522\"\u003e\n\u003ch3 data-start=\"2524\" data-end=\"2573\"\u003eRequired Selection — Model \u0026amp; PCM Verification\u003c\/h3\u003e\n\u003cp data-start=\"2574\" data-end=\"2673\"\u003e\u003cstrong data-start=\"2574\" data-end=\"2673\"\u003eYou must select the correct model and PCM board version from the dropdown menu before checkout.\u003c\/strong\u003e\u003c\/p\u003e\n\u003col data-start=\"2675\" data-end=\"2909\"\u003e\n\u003cli data-start=\"2675\" data-end=\"2731\"\u003e\n\u003cp data-start=\"2678\" data-end=\"2731\"\u003eConfirm your stove model (\u003cstrong data-start=\"2704\" data-end=\"2728\"\u003eHP41, HP42, or HP75c\u003c\/strong\u003e)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2732\" data-end=\"2857\"\u003e\n\u003cp data-start=\"2735\" data-end=\"2751\"\u003eFor HP41 \/ HP42:\u003c\/p\u003e\n\u003cul data-start=\"2755\" data-end=\"2857\"\u003e\n\u003cli data-start=\"2755\" data-end=\"2778\"\u003e\n\u003cp data-start=\"2757\" data-end=\"2778\"\u003eInspect the PCM board\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2782\" data-end=\"2857\"\u003e\n\u003cp data-start=\"2784\" data-end=\"2857\"\u003eIdentify the transformer color (fully yellow or half yellow \/ half red)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2858\" data-end=\"2909\"\u003e\n\u003cp data-start=\"2861\" data-end=\"2909\"\u003eSelect the \u003cstrong data-start=\"2872\" data-end=\"2909\"\u003ematching option from the dropdown\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp data-start=\"2911\" data-end=\"2993\"\u003e⚠️ \u003cstrong data-start=\"2914\" data-end=\"2993\"\u003eIncorrect selection may cause improper operation or a non-functional stove.\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"2995\" data-end=\"2998\"\u003e\n\u003ch3 data-start=\"3000\" data-end=\"3035\"\u003eCondition \u0026amp; Cosmetic Disclosure\u003c\/h3\u003e\n\u003cp data-start=\"3036\" data-end=\"3248\"\u003e\u003cem data-start=\"3036\" data-end=\"3050\"\u003ePlease Note:\u003c\/em\u003e This control panel is \u003cstrong data-start=\"3073\" data-end=\"3107\"\u003ebrand new and fully functional\u003c\/strong\u003e. The plastic housing may show \u003cstrong data-start=\"3138\" data-end=\"3188\"\u003eminor cosmetic scuffs or surface imperfections\u003c\/strong\u003e. These are cosmetic only and do \u003cstrong data-start=\"3221\" data-end=\"3228\"\u003enot\u003c\/strong\u003e affect performance.\u003c\/p\u003e\n\u003cp data-start=\"3250\" data-end=\"3374\"\u003eThis is due to the manufacturer’s \u003cstrong data-start=\"3284\" data-end=\"3336\"\u003eeco-friendly practice of reusing plastic casings\u003c\/strong\u003e to reduce waste and production costs.\u003c\/p\u003e\n\u003chr data-start=\"3376\" data-end=\"3379\"\u003e\n\u003ch3 data-start=\"3381\" data-end=\"3404\"\u003eWhat You’ll Receive\u003c\/h3\u003e\n\u003cul data-start=\"3405\" data-end=\"3538\"\u003e\n\u003cli data-start=\"3405\" data-end=\"3453\"\u003e\n\u003cp data-start=\"3407\" data-end=\"3453\"\u003e(1) Replacement User Interface Control Panel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3454\" data-end=\"3517\"\u003e\n\u003cp data-start=\"3456\" data-end=\"3517\"\u003eProgramming matched to selected model and PCM configuration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3518\" data-end=\"3538\"\u003e\n\u003cp data-start=\"3520\" data-end=\"3538\"\u003ePackaging may vary\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3540\" data-end=\"3543\"\u003e\n\u003ch3 data-start=\"3545\" data-end=\"3577\"\u003eImportant Ordering Checklist\u003c\/h3\u003e\n\u003cp data-start=\"3578\" data-end=\"3613\"\u003eBefore placing your order, confirm:\u003c\/p\u003e\n\u003col data-start=\"3614\" data-end=\"3800\"\u003e\n\u003cli data-start=\"3614\" data-end=\"3657\"\u003e\n\u003cp data-start=\"3617\" data-end=\"3657\"\u003eStove model (\u003cstrong data-start=\"3630\" data-end=\"3654\"\u003eHP41, HP42, or HP75c\u003c\/strong\u003e)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3658\" data-end=\"3702\"\u003e\n\u003cp data-start=\"3661\" data-end=\"3702\"\u003eThermocouple-based Proof of Fire system\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3703\" data-end=\"3756\"\u003e\n\u003cp data-start=\"3706\" data-end=\"3756\"\u003eFor HP41 \/ HP42, correct \u003cstrong data-start=\"3731\" data-end=\"3756\"\u003ePCM transformer color\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3757\" data-end=\"3800\"\u003e\n\u003cp data-start=\"3760\" data-end=\"3800\"\u003eCorrect dropdown selection has been made\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"ComfortBilt","offers":[{"title":"HP41 (Fully Yellow PCM)","offer_id":46216482324630,"sku":"CB-CP-HP41A","price":129.99,"currency_code":"USD","in_stock":false},{"title":"HP42 (Fully Yellow PCM)","offer_id":46216482357398,"sku":"CB-CP-HP42A","price":129.99,"currency_code":"USD","in_stock":false},{"title":"HP41 (Half Yellow\/Half Red PCM)","offer_id":46216484323478,"sku":"CB-CP-HP41B","price":129.99,"currency_code":"USD","in_stock":false},{"title":"HP42 (Half Yellow\/Half Red PCM)","offer_id":46216484356246,"sku":"CB-CP-HP42B","price":129.99,"currency_code":"USD","in_stock":false},{"title":"HP75c","offer_id":46216484389014,"sku":"CB-CP-HP75C","price":129.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0411\/0670\/2486\/files\/controlpanel.jpg?v=1709324821","url":"https:\/\/www.comfortbilt.net\/products\/replacement-user-interface-control-panel-for-hp41-hp42-and-hp75c-pellet-stoves","provider":"ComfortBilt","version":"1.0","type":"link"}